Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38519014

RESUMEN

OBJECTIVE: Studies demonstrate that heart transplantation can be performed safely in septuagenarians. We evaluate the outcomes of septuagenarians undergoing heart transplantation after the US heart allocation change in 2018. METHODS: The United Network for Organ Sharing registry was used to identify heart transplant recipients aged 70 years or more between 2010 and 2021. Primary outcomes were 90-day and 1-year mortality. Kaplan-Meier, multivariable Cox proportional hazards, and accelerated failure time models were used for unadjusted and risk-adjusted analyses. RESULTS: A total of 27,403 patients underwent heart transplantation, with 1059 (3.9%) aged 70 years or more. Patients aged 70 years or more increased from 3.7% before 2018 to 4.5% after 2018 (P = .003). Patients aged 70 years or more before 2018 had comparable 90-day and 1-year survivals relative to patients aged less than 70 years (90 days: 93.8% vs 94.2%, log-rank P = .650; 1 year: 89.4% vs 91.1%, log-rank P = .130). After 2018, septuagenarians had lower 90-day and 1-year survivals (90 days: 91.4% vs 95.0%, log-rank P = .021; 1 year: 86.5% vs 90.9%, log-rank P = .018). Risk-adjusted analysis showed comparable 90-day mortality (hazard ratio, 1.29; 0.94-1.76, P = .110) but worse 1-year mortality (hazard ratio, 1.32; 1.03-1.68, P = .028) before policy change. After policy change, both 90-day and 1-year mortalities were higher (90 days: HR, 1.99; 1.23-3.22, P = .005; 1 year: hazard ratio, 1.71; 1.14-2.56, P = .010). An accelerated failure time model showed comparable 90-day (0.42; 0.16-1.44; P = .088) and 1-year (0.48; 0.18-1.26; P = .133) survival postallocation change. CONCLUSIONS: Septuagenarians comprise a greater proportion of heart transplant recipients after the allocation change, and their post-transplant outcomes relative to younger recipients have worsened.

2.
ASAIO J ; 70(2): 99-106, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37816019

RESUMEN

Right ventricular failure contributes significantly to morbidity and mortality after left ventricular assist device implantation. Recent data suggest a less invasive strategy (LIS) via thoracotomy may be associated with less right ventricular failure than conventional median sternotomy (CMS). However, the impact of these approaches on load-independent right ventricular (RV) contractility and RV-pulmonary arterial (RV-PA) coupling remains uncertain. We hypothesized that the LIS approach would be associated with preserved RV contractility and improved RV-PA coupling compared with CMS. We performed a retrospective study of patients who underwent durable, centrifugal left ventricular assist device implantation and had paired hemodynamic assessments before and after implantation. RV contractility (end-systolic elastance [Ees]), RV afterload (pulmonary effective arterial elastance [Ea]), and RV-PA coupling (Ees/Ea) were determined using digitized RV pressure waveforms. Forty-two CMS and 21 LIS patients were identified. Preimplant measures of Ees, Ea, and Ees/Ea were similar between groups. After implantation, Ees declined significantly in the CMS group (0.60-0.40, p = 0.008) but not in the LIS group (0.67-0.58, p = 0.28). Coupling (Ees/Ea) was unchanged in CMS group (0.54-0.59, p = 0.80) but improved significantly in the LIS group (0.58-0.71, p = 0.008). LIS implantation techniques may better preserve RV contractility and improve RV-PA coupling compared with CMS.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Hipertensión Pulmonar , Disfunción Ventricular Derecha , Humanos , Estudios Retrospectivos , Arteria Pulmonar , Ventrículos Cardíacos , Insuficiencia Cardíaca/cirugía
3.
Ann Thorac Surg ; 117(2): 404-411, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37479131

RESUMEN

BACKGROUND: Heart transplantation is relatively contraindicated in morbidly obese patients because of increased morbidity and mortality. This study identified risk factors for post-heart transplantation mortality in obese patients with a left ventricular assist device (LVAD). METHODS: The United Network for Organ Sharing database was used to identify patients with a body mass index ≥35 kg/m2 who had a durable LVAD at the time of isolated heart transplantation between 2010 and 2021. The primary outcome was post-heart transplantation 1-year mortality. Multivariable Cox regression modeling was used to identify significant risk factors for 1-year mortality. Receiver-operating characteristic analyses were performed to identify optimal thresholds for continuous variables associated with the primary outcome. Patients were stratified by the number of risk factors, and Kaplan-Meier analysis was used to compare survival. RESULTS: A total of 1222 obese patients were bridged to heart transplantation with a durable LVAD. Six risk factors were identified as significantly associated with 1-year post-heart transplantation mortality: recipient age >62.5 years, body mass index >36.6 kg/m2, bilirubin level >0.95 mg/dL, cold ischemic time >3.7 hours, recipient-donor sex mismatch, and pretransplantation mechanical ventilation. The distribution of cumulative risk factors was as follows: 8.6% with 0, 30.6% with 1, 37.0% with 2, and 23.8% patients with ≥3 risk factors. The 1-year survival rate decreased significantly from 96.0% in those patients with 0 risk factors to 77.6% in those with 3 or more risk factors. CONCLUSIONS: These data provide a useful guide for risk stratification and patient selection in obese LVAD candidates being considered for heart transplantation.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Obesidad Mórbida , Humanos , Persona de Mediana Edad , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Resultado del Tratamiento , Factores de Riesgo , Estudios Retrospectivos
4.
JACC Case Rep ; 27: 102106, 2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-38094729

RESUMEN

Cardiogenic shock in pregnancy is rare but is associated with significant morbidity and mortality. Timely recognition with multidisciplinary management is necessary for optimal maternal and fetal outcomes. Here we present a case of cardiogenic shock in the antepartum period managed with mechanical circulatory support as a bridge to pregnancy viability.

6.
J Card Fail ; 29(9): 1288-1295, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37230313

RESUMEN

BACKGROUND: Heart transplantation is the gold-standard therapy for end-stage heart failure, but rates of donor-heart use remain low due to various factors that are often not evidence based. The impact of donor hemodynamics obtained via right-heart catheterization on recipient survival remains unclear. METHODS: The United Network for Organ Sharing registry was used to identify donors and recipients from September 1999-December 2019. Donor hemodynamics data were obtained and analyzed using univariate and multivariable logistical regression, with the primary endpoints being 1- and 5-year post-transplant survival. RESULTS: Of the 85,333 donors who consented to heart transplantation during the study period, 6573 (7.7%) underwent right-heart catheterization, of whom 5531 eventually underwent procurement and transplantation. Donors were more likely to undergo right-heart catheterization if they had high-risk criteria. Recipients who had donor hemodynamic assessment had 1- and 5-year survival rates similar to those without donor hemodynamic assessment (87% vs 86%, 1 year). Abnormal hemodynamics were common in donor hearts but did not impact recipient survival rates, even when risk-adjusted in multivariable analysis. CONCLUSIONS: Donors with abnormal hemodynamics may represent an opportunity to expand the pool of viable donor hearts.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Humanos , Donantes de Tejidos , Insuficiencia Cardíaca/cirugía , Hemodinámica , Sistema de Registros , Estudios Retrospectivos
7.
J Heart Lung Transplant ; 42(2): 145-149, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36481112

RESUMEN

Equipoise remains about how best to measure cardiac output (CO) in patients with left ventricular assist devices (LVAD). In this study, direct Fick CO was compared with thermodilution (TD) and indirect Fick (iFick) CO in 61 LVAD patients. TD and LaFarge iFick showed moderate correlation with direct Fick (R2 = 0.49 and R2 = 0.38, p < 0.001 for both), while Dehmer and Bergstra iFick showed poor correlation with direct Fick (R2 = 0.29 and R2 = 0.31, p < 0.001 for both). Absolute bias between all CO estimation techniques and direct Fick CO was lowest for TD compared to iFick methods but significant for all methods. All methods tended to overestimate CO compared to direct Fick, with greatest overestimation present in those with the lowest measured direct Fick CO. Bias and frequency of significant discrepancy were least using TD and Lafarge iFick CO estimation methods in this study, with TD CO demonstrating modestly better correlation and less heteroscedasticity compared to Lafarge.


Asunto(s)
Corazón Auxiliar , Humanos , Gasto Cardíaco , Termodilución/métodos , Consumo de Oxígeno , Monitoreo Fisiológico
8.
JACC Case Rep ; 28: 102133, 2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-38204543

RESUMEN

A 60-year-old man presented with heart failure symptoms and was found to have a calcified pericardial effusion consistent with "milk of calcium" and constrictive physiology. The patient received a pericardiectomy and has had favorable outcomes at his 1-year follow-up. There are minimal reports of calcific pericardial effusion with constrictive pathology.

9.
J Card Surg ; 37(12): 4713-4718, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36321713

RESUMEN

PURPOSE: Recent changes in the market for left ventricular assist devices have resulted in the HeartMate 3 (HM3) being the only commercially-available device. This study evaluates the outcomes of patients with a HM3 waitlisted for and undergoing orthotopic heart transplantation (OHT). METHODS: Patients waitlisted for isolated OHT with a HM3 or undergoing OHT after bridge-to-transplant (BTT) with a HM3 between 2015 and 2021 were identified from the UNOS registry and included in this study. Propensity matching was used to compare outcomes of BTT-HM3 versus primary OHT. RESULTS: A total of 1321 patients supported with a HM3 underwent OHT during our study period. Unadjusted 30-day, 90-day, and 1-year survival following OHT in the BTT-HM3 cohort was 96.5%, 94.4%, and 90.7%, respectively. In propensity-matched analysis, 1103 BTT-HM3 patients were compared with 1103 primary OHT patients. Rates of post-OHT stroke were higher in the BTT-HM3 group (4.4% vs. 2.0%, p = .001). The BTT-HM3 group had lower 30-day survival (96.2% vs. 97.4%, p = .033) although 90-day (94.2% vs. 95.3%, p = .103) and 1-year survival (90.4% vs. 91.7%, p = .216) were comparable. A total of 1251 patients were supported with a HM3 at the time of OHT listing during the study period. At the time of this analysis, 60 (4.5%) remained on the waitlist, 991 (75.0%) underwent OHT, and 119 (9.0%) died or clinically deteriorated with waitlist removal. CONCLUSIONS: The HM3 is a viable method for BTT with acceptable waitlist outcomes. Although 1-year survival is comparable to primary OHT, early outcomes are worse, suggesting that refinement of patient selection and perioperative management is prudent to optimizing outcomes.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Humanos , Insuficiencia Cardíaca/cirugía , Estudios Retrospectivos , Trasplante de Corazón/métodos , Factores de Tiempo , Resultado del Tratamiento
10.
J Heart Lung Transplant ; 41(12): 1716-1726, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35934606

RESUMEN

BACKGROUND: Early right heart failure (RHF) remains a major source of morbidity and mortality after left ventricular assist device (LVAD) implantation, yet efforts to predict early RHF have proven only modestly successful. Pharmacologic unloading of the left ventricle may be a risk stratification approach allowing for assessment of right ventricular and hemodynamic reserve. METHODS: We performed a multicenter, retrospective analysis of patients who had undergone continuous-flow LVAD implantation from October 2011 to April 2020. Only those who underwent vasodilator testing with nitroprusside during their preimplant right heart catheterization were included (n = 70). Multivariable logistic regression was used to determine independent predictors of early RHF as defined by Mechanical Circulatory Support-Academic Research Consortium. RESULTS: Twenty-seven patients experienced post-LVAD early RHF (39%). Baseline clinical characteristics were similar between patients with and without RHF. Patients without RHF, however, achieved higher peak stroke volume index (SVI) (30.1 ± 8.8 vs 21.7 ± 7.4 mL/m2; p < 0.001; AUC: 0.78; optimal cut-point: 22.1 mL/m2) during nitroprusside administration. Multivariable analysis revealed that peak SVI was significantly associated with early RHF, demonstrating a 16% increase in risk of early RHF per 1 ml/m2 decrease in SVI. A follow up cohort of 10 consecutive patients from July 2020 to October 2021 resulted in all patients being categorized appropriately in regards to early RHF versus no RHF according to peak SVI. CONCLUSION: Peak SVI with nitroprusside administration was independently associated with post-LVAD early RHF while resting hemodynamics were not. Vasodilator testing may prove to be a strong risk stratification tool when assessing LVAD candidacy though additional prospective validation is needed.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Disfunción Ventricular Derecha , Humanos , Estudios Retrospectivos , Nitroprusiato , Corazón Auxiliar/efectos adversos , Insuficiencia Cardíaca/cirugía , Volumen Sistólico , Vasodilatadores/uso terapéutico
11.
J Card Fail ; 28(11): 1584-1592, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35597511

RESUMEN

BACKGROUND: Multiple studies have shown better outcomes for simultaneous heart-kidney transplant (sHKT) than for isolated orthotopic heart transplant (iOHT) in recipients with chronic kidney disease (CKD). However, outcomes in patients supported by durable left ventricular assist devices (LVADs) have not been well studied. METHODS: Patients with durable LVADs and stage 3 or higher CKD (eGFR < 60 mL/min/1.73 m2) undergoing iOHT or sHKT between 2008 and 2020 were identified from the United Network for Organ Sharing registry. A Kaplan-Meier survival analysis with associated log-rank test was conducted to compare post-transplant survival rates. Multivariable modeling was used to identify risk-adjusted predictors of 1 year post-transplant mortality. RESULTS: We identified 4375 patients; 366 underwent sHKT, and 4009 underwent iOHT. The frequency of sHKT increased during the study period. The 1-year post-transplant survival rate was worse in patients after sHKT than in patients after iOHT (80.3% vs 88.3%; P < 0.001) and persisted up to 5 years post-transplant (P = 0.001). sHKT recipients were more likely to require dialysis after transplantation and had longer hospital lengths of stay (P < 0.001). Multivariable analysis showed that sHKT remained an independent risk factor for mortality at 1 year (OR 1.58; P = 0.002). CONCLUSIONS: sHKT is becoming more common in patients with durable LVADs. Compared with iOHT, patients with sHKTs have worse short- and long-term survival rates and are more likely to require post-transplant dialysis.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Trasplante de Riñón , Insuficiencia Renal Crónica , Humanos , Resultado del Tratamiento , Estudios Retrospectivos , Insuficiencia Renal Crónica/etiología
12.
ASAIO J ; 68(6): 800-807, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35380184

RESUMEN

The use of venoarterial extracorporeal membrane oxygenation (VA-ECMO) following acute myocardial infarction with cardiogenic shock (AMI-CS) is increasing, but the ability to predict favorable outcomes with support remains limited. We retrospectively reviewed all patients with AMI-CS supported with VA-ECMO between December 2008 and June 2018. One hundred twenty-six patients received VA-ECMO for AMI-CS during the study period; of these, 39 (31.0%) experienced ventricular recovery and were discharged while 87 (69.0%) did not recover, with 71 (56.3%) dying in the hospital and 16 (12.7%) surviving to discharge with either left ventricular assist device or heart transplant. TIMI 3 flow in culprit artery (OR, 4.01; 95% CI, 1.25-12.77; p = 0.02), serum lactate (OR, 0.89; 95% CI, 0.80-0.99; p = 0.04), and prompt revascularization (OR, 3.39; 95% CI, 1.18-9.81; p = 0.02) were independent predictors of ventricular recovery. Four variables emerged as independent predictors of in-hospital mortality and were used to create the AMI-ECMO Risk Score: age >70 years, creatinine >1.5 mg/dL, serum lactate > 4.0 mmol/L, and lack of TIMI 3 flow in culprit artery. In patients supported with VA-ECMO for AMI-CS, prompt, successful revascularization, and lower serum lactate were associated with ventricular recovery while younger age, lower serum lactate, and creatinine, and successful revascularization were associated with survival to discharge. The AMI-ECMO risk score is a simple tool that can help risk stratify patients with AMI-CS being considered for VA-ECMO support.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Infarto del Miocardio , Anciano , Creatinina , Humanos , Lactatos , Infarto del Miocardio/complicaciones , Infarto del Miocardio/cirugía , Estudios Retrospectivos , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia
13.
Heart Surg Forum ; 25(2): E297-E299, 2022 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-35486052

RESUMEN

Coronary artery pseudoaneurysms are extremely rare and most often occur after trauma or endovascular procedures [Aoki 2008; Kar 2017]. Delay in diagnosis or treatment may lead to coronary thrombosis with resultant ischemia or hemorrhage subsequent tamponade. Here, we present the case of a 66-year-old female who developed a coronary artery pseudoaneurysm of a non-grafted vessel three weeks after coronary artery bypass grafting. To avoid re-sternotomy, the pseudoaneurysm was successfully managed with a covered coronary stent and mini-left anterior thoracotomy to evacuate the hemopericardium and relieve tamponade.


Asunto(s)
Aneurisma Falso , Vasos Coronarios , Anciano , Aneurisma Falso/diagnóstico , Aneurisma Falso/etiología , Aneurisma Falso/cirugía , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Femenino , Humanos , Stents , Esternotomía
14.
Ann Thorac Surg ; 114(4): 1386-1394, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35247342

RESUMEN

BACKGROUND: In 2018, the United Network for Organ Sharing implemented a change in heart allocation policy resulting in increased organ ischemia times in early analyses. This study evaluated the effect of ischemia time on 1-year mortality in the context of allocation policy changes implemented in 2006 and 2018. METHODS: The United Network for Organ Sharing registry was used to identify adults undergoing heart transplantation from 2000 to 2020. Patients were stratified by the allocation policy era in which they received a transplant (2000-June 2006, July 2006-October 2018, October 2018-2020) and by ischemia time, defined as normal (≤4 hours) and prolonged (>4 hours). One-year survival was estimated using Kaplan-Meier analysis. Cox regression was used to determine risk-adjusted hazards for ischemia time on 1-year mortality. RESULTS: There were 40 052 patients included for analysis. Ischemia times were normal in 32 585 (81.36%) and prolonged in 7467 (18.64%) patients. The proportion of transplantations with prolonged ischemia times increased with each subsequent policy era. After the 2018 policy change, 1-year survival was 90.92% with normal ischemia times vs 87.52% with prolonged ischemia times (P < .001). Ischemia time independently predicted 1-year mortality in each era with a hazard ratio of 1.20 per hour (P = .004) in the current era. CONCLUSIONS: Prolonged ischemia times occur in a minority of cases but are increasing in frequency. The independent risk of prolonged ischemia time on 1-year mortality persists despite advances in storage technology and should remain a consideration in donor-recipient matching.


Asunto(s)
Trasplante de Corazón , Obtención de Tejidos y Órganos , Adulto , Humanos , Isquemia , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Tiempo , Donantes de Tejidos
15.
Clin Transplant ; 36(4): e14581, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34974630

RESUMEN

BACKGROUND: This study evaluated the outcomes of combined heart-kidney transplantation in the United States using hepatitis C positive (HCV+) donors. METHODS: Adults undergoing combined heart-kidney transplantation from 2015 to 2020 were identified in the United Network for Organ Sharing registry. Patients were stratified by donor HCV status. Kaplan-Meier curves with multivariable Cox regression models were used for risk-adjustment in a propensity-matched cohort. RESULTS: A total of 950 patients underwent heart-kidney transplantation of which 7.8% (n = 75) used HCV+ donors; 68% (n = 51) were viremic and 32% (n = 24) were non-viremic donors. Unadjusted 1-year recipient survival was similar between HCV+ versus HCV- donors (84% vs 88%, respectively; P = .33). Risk-adjusted analysis in the propensity-matched cohort showed HCV+ donor use did not confer increased risk of 1-year mortality (hazard ratio .63, 95% CI .17-2.32; P = .49). Sub-group analysis showed viremic and non-viremic HCV+ donors had similar 1-year survival as well (84% vs 84%; P = .95). CONCLUSIONS: Compared with recipients of HCV- donor dual heart-kidney transplants, recipients of HCV+ organs had comparable 1-year survival and clinical outcomes after combined transplantation. Although future studies should evaluate other outcomes related to HCV+ donor use, this practice appears safe and should be expanded further in the heart-kidney transplant population.


Asunto(s)
Hepatitis C , Trasplante de Riñón , Adulto , Hepacivirus , Hepatitis C/cirugía , Humanos , Riñón , Estudios Retrospectivos , Donantes de Tejidos , Estados Unidos/epidemiología , Viremia
16.
Ann Thorac Surg ; 114(3): 650-658, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35085525

RESUMEN

BACKGROUND: This study evaluated trends and outcomes of patients undergoing heart transplantation for peripartum cardiomyopathy (PPCM) over the past 3 decades. METHODS: The United Network for Organ Sharing registry was used to identify patients undergoing isolated heart transplantation between 1987 and 2020. Patients were stratified by the decade of transplantation. Overall survival was compared using Kaplan-Meier analysis, and risk-adjustment was performed using Cox proportional hazards modeling. RESULTS: A total of 76 009 heart transplantations occurred in the study period, including 20 352 female patients and 809 female patients with PPCM. The frequency of transplantation for PPCM increased over the study period (P = .015). Among female patients, PPCM was significantly associated with 1-year mortality compared with nonischemic cardiomyopathy (hazard ratio, 1.38; 95% CI, 1.11-1.69; P = .004). Among patients with PPCM, Black and Hispanic heart transplant recipients had increased 1-year posttransplant mortality risk compared with White recipients. On Kaplan-Meier survival analysis, early and midterm survival was significantly worse in patients with PPCM compared with other female patients. The 5-, 10-, and 15-year survivals in patients with PPCM were 66.5%, 49.0%, and 40.2% compared with 74.3%, 56.0%, and 37.5% in female heart transplant recipients with other heart failure diagnoses, respectively (P < .001). Survival improved significantly in patients who underwent heart transplantation for PPCM in the latest decade from 2010 to 2020 compared with earlier decades (P < .001), and this improvement was most marked for Black recipients. CONCLUSIONS: Patients who underwent heart transplantation for PPCM have a significantly elevated risk for 1-year mortality compared with other female transplant recipients. However, survival among these patients has improved in the last decade, particularly for Black transplant recipients.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Trasplante de Corazón , Trastornos Puerperales , Cardiomiopatías/complicaciones , Femenino , Humanos , Periodo Periparto , Estudios Retrospectivos
17.
Clin Transplant ; 36(3): e14546, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34843123

RESUMEN

BACKGROUND: This study compared outcomes of patients bridged with either the Heartware HVAD or Heartmate 3 (HM3) device to orthotopic heart transplantation (OHT). METHODS: The United Network of Organ Sharing registry was queried to perform two separate analyses of adult, isolated OHT candidates bridged with HVAD or HM3. First, waitlist outcomes were compared among patients waitlisted 1/1/2015-3/20/2020. Second, posttransplant survival was compared among those transplanted 1/1/2015-3/20/2020. RESULTS: Two thousand two hundred fifty-five candidates were waitlisted within the study period, 1587 (70.4%) bridged with HVAD and 668 (29.6%) with HM3. At 1 year from waitlisting, cumulative incidence of OHT higher in the HVAD cohort (p < .001). During the same time period, 2643 patients underwent OHT, 2154 (81.5%) with prior HVAD and 489 (18.5%) with HM3. Yearly proportions of patients bridged with HM3 increased across the study period and decreased for HVAD (p < .001). HM3-bridged recipients had shorter waitlist times, longer graft cold ischemic times, and experienced a higher rate of posttransplant dialysis requirement. Unadjusted and risk-adjusted posttransplant mortality rates were similar between both groups. CONCLUSIONS: Posttransplant survival is equivalent regardless of device type used for bridging. However, HM3 patients had lower likelihood of reaching transplantation, which may be a reflection of the recent heart allocation policy changes.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Trasplantes , Adulto , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón/efectos adversos , Corazón Auxiliar/efectos adversos , Humanos , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento , Listas de Espera
18.
J Card Surg ; 37(3): 590-599, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34967979

RESUMEN

BACKGROUND AND AIM: This study evaluated the impact of changes in renal function during the waitlist period on posttransplant outcomes of orthotopic heart transplantation (OHT). METHODS: The United Network for Organ Sharing registry was used to identify adult patients undergoing isolated OHT from 2010 to 2020. Patients were stratified by whether their National Kidney Foundation chronic kidney disease (CKD) stage improved, worsened, or remained unchanged between listing and transplantation. Univariate analysis and multivariable Cox regression were conducted to determine whether a change in estimated glomerular filtration rate (eGFR) or change in CKD stage predicted 1-year mortality after OHT. RESULTS: Of 22,746 patients, the majority of patients remained in the same CKD stage (59.6%), and the frequencies of patients progressing to improved (19.3%) and worsened (21.1%) CKD stages were similar. Temporary mechanical circulatory support (MCS) was associated with improved CKD stage and durable MCS with worsened CKD stage (p < .001). Post-OHT dialysis was most common in patients with worsened CKD stage (13.2%) and least common in the improved cohort (9.4%) (p < .001). Kaplan-Meier unadjusted 1-year survival rates after OHT were similar between CKD change groups (log-rank p = .197). Multivariable analysis demonstrated no risk-adjusted effect of change in eGFR (p = .113) or change in CKD stage (p = .076) on 1-year mortality after OHT. CONCLUSIONS: Approximately 20% of patients improve CKD stage and 20% worsen CKD stage between listing and OHT, with the remaining 60% having unchanged CKD stage. Worsening CKD stage predicts increased likelihood of post-OHT dialysis, but CKD stage change does not predict 1-year survival following OHT.


Asunto(s)
Trasplante de Corazón , Tasa de Filtración Glomerular , Humanos , Riñón/fisiología , Estudios Retrospectivos , Listas de Espera
19.
ASAIO J ; 67(10): 1119-1124, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34225277

RESUMEN

Postcardiotomy shock (PCS) has historically been associated with substantial morbidity and mortality. Mortality at discharge is reportedly more than 60%. We investigated the outcomes of our standardized approach to veno-arterial extracorporeal membrane oxygenation (ECMO) management for PCS. We retrospectively reviewed 60 consecutive PCS patients who required ECMO following major cardiac surgery from January 2017 to September 2019. Index surgery included CABG (n = 10), valve (n = 23), valve and CABG (n = 12), root surgery (n = 10), and other (n = 5). Median lactate level, systolic blood pressure, and mean pulmonary artery pressure before ECMO were 4.0 mmol/L, 80 mm Hg, and 29 mm Hg, respectively. Fifty-nine patients (98%) were on two vasopressors, and 54 (90%) were on at least two inotropes. Vasoactive-Inotropic Score was 30 (IQR, 25-49). Eighty percent of patients received peripheral ECMO. Median ECMO flow index was 1.61 (IQR, 1.4-2.0) L/min/m2. Anticoagulation was not given in 12 (20%) patients during ECMO support. Major adverse events included chest re-exploration (15%), stroke (6.7%), renal replacement therapy (22%), and limb ischemia (5%). In-hospital mortality was 33%. This study suggests that a standardized approach with a dedicated ECMO team is feasible and may improve outcomes of PCS.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Oxigenación por Membrana Extracorpórea , Choque , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Oxigenación por Membrana Extracorpórea/efectos adversos , Mortalidad Hospitalaria , Humanos , Estudios Retrospectivos , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia
20.
J Card Fail ; 27(12): 1367-1373, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34161806

RESUMEN

BACKGROUND: Heart failure predisposes to intracardiac thrombus (ICT) formation. There are limited data on the prevalence and impact of preexisting ICT on postoperative outcomes in left ventricular assist device patients. We examined the risk for stroke and death in this patient population. METHODS AND RESULTS: We retrospectively studied patients who were implanted with HeartMate (HM) II or HM3 between February 2009 and March 2019. Preoperative transthoracic echocardiograms, intraoperative transesophageal echocardiograms and operative reports were reviewed to identify ICT. There were 525 patients with a left ventricular assist device (median age 60.6 years, 81.8% male, 372 HMII and 151 HM3) included in this analysis. An ICT was identified in 44 patients (8.4%). During the follow-up, 43 patients experienced a stroke and 55 died. After multivariable adjustment, presence of ICT increased the risk for the composite of stroke or death at 6-month (hazard ratio [HR] 1.82, 95% confidence interval [CI] 1.00-3.33, P = .049). Patients with ICT were also at higher risk for stroke (HR 2.45, 95% CI 1.14-5.28, P = .021) and death (HR 2.36, 95% CI 1.17-4.79 P = .016) at 6 months of follow-up. CONCLUSIONS: The presence of ICT is an independent predictor of stroke and death at 6 months after left ventricular assist device implantation. Additional studies are needed to help risk stratify and optimize the perioperative management of this patient population.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular , Trombosis , Femenino , Insuficiencia Cardíaca/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...